Olympus UIS2 User Manual

Browse online or download User Manual for Microscopes Olympus UIS2. Olympus UIS2 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
MICROSCOPE
COMPONENTS GUIDE
Choosing The Ideal UIS2 Optics Components For Your Equipment
2006-11
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - COMPONENTS GUIDE

MICROSCOPE COMPONENTS GUIDEChoosing The Ideal UIS2 Optics Components For Your Equipment2006-11

Page 2

UIS2 OBJECTIVE LENSES9Long WD M Plan SemiApochromat (WD: Working Distance)LMPLFLN seriesLong working distance Plan SemiApochromat objective lenses, gi

Page 3 - CONTENTS

10UIS2 OBJECTIVE LENSESUnit: mmM Plan AchromatMPLN seriesPlan Achromat objective lenses providing excellent image flatness up to F.N. 22. MPLN 5x 0.1

Page 4 - UIS2/UIS:

UIS2 OBJECTIVE LENSES11LCD Long WD M Plan SemiApochromatLCPLFLN-LCD seriesPerfect objective lens series for observation of LCD panels and other sample

Page 5 - WELCOME TO UIS2/UIS OPTICS

UIS OBJECTIVE LENSES12Unit: mmø5.6ø16.5ø20ø28WD=0.934.738.740.1(44.1)45 4.5ø20.3236.840.741.7(44.7)WD=0.3454.5ø8ø16.6ø20.2ø28ø20.32ø5.3ø16.5ø20.240.74

Page 6 - SYSTEM DIAGRAM

13UIS OBJECTIVE LENSESIR Long WD M Plan SemiApochromat/IR M Plan SemiApochromatLMPlan-IR series/MPlan-IRIR objective lenses which compensate for aberr

Page 7

UIS2 OBJECTIVE LENSES14M Plan SemiApochromat BD (BD:Brightfield/Darkfield)MPLFLN-BD seriesPlan SemiApochromat objective lenses, giving high-level corr

Page 8 - UIS2/UIS OBJECTIVE LENSES

15UIS2 OBJECTIVE LENSESScrew: W26x0.706Unit: mmMPLFLN 5xBDP 0.15 12.0 36 95.5 50 4.4 59 50 5.3 59MPLFLN 10xBDP 0.25 6.5 18 83.3 100 2.2 18 100 2.7 18M

Page 9 - M Plan SemiApochromat

UIS2 OBJECTIVE LENSES16Long WD M Plan SemiApochromat BDLMPLFLN-BD seriesLong working distance Plan SemiApochromat objective lenses, giving high-level

Page 10 - LMPLFLN series

UIS2 OBJECTIVE LENSES17M Plan Achromat BDMPLN-BD seriesPlan Achromat objective lenses providing excellent image flatness up to F.N. 22. MPLN 5xBD 0.1

Page 11 - M Plan Achromat

18UIS OBJECTIVE LENSESø264142.543.2(44.69)4.5WD=0.31ø10ø23ø27ø29ø3245MPlanApo100xBDM Plan Apochromat BDMPlanApo-BDHighest class Plan Apochromat object

Page 12 - LCPLFLN-LCD series

The wide range of Olympus components introduced here allows users in such diverse fields as research, inspection and production to take advantage of t

Page 13 - Super Long WD M Plan Achromat

BXFM frameBXFM-FWidely used system that allows use in combination with fiber illumination, motorized revolving nosepiece and telan lens unit.Can easil

Page 14 - UIS OBJECTIVE LENSES

MICROSCOPE SYSTEM BXFM20BXFMBXFM-F+BXFM-ILH+BXFM-ILHSPUAccommodates the reflected light brightfield/darkfield and fluorescence illuminators.Weight: 3.

Page 15 - MPLFLN-BD series

MICROSCOPE SYSTEM BXFM21ø32169(Stroke)19-4912484208290204045106 18792.5Specimen surfaceBXFM-S combination sampleBXFM-F+BXFM-ILHS+TR30-2+U-KMAS+U-LH100

Page 16 - MPLFLN-BDP series

MICROSCOPE SYSTEM BXFM22U-STCompact standWeight: 5kg Unit: mmWeight: 1.8kg10673 14388ø110133ø3249 1332035ø40130503ø25Ø32214~435622350300180º9050.530º2

Page 17 - LMPLFLN-BD series

ILLUMINATION UNITS23Universal reflected light illuminatorBX-URA2Suitable for observations ranging from brightfield to fluorescence. Six mirror units

Page 18 - M Plan Achromat BD

ILLUMINATION UNITS24170 (Distance to the light axis)Convex section(2-4) for positioning 3.5Less than R62182 (Revolving nosepiece relief dimension)5

Page 19 - M Plan Apochromat BD

LAMP HOUSING & ACCESSORIES25Reflected light illuminator for BFU-KMASVery compact reflected light illuminator with reduced depth.Weight: 1.2kgUnit:

Page 20 - BXFM frame

LAMP HOUSING & ACCESSORIES26Lamp housingsVarious different lamp housings are available, for use with different light sources: choose to suit the i

Page 21 - BXFM-F+BXFM-ILH+BXFM-ILHSPU

LAMP HOUSING & ACCESSORIES2731.5 (dimensions for installation)Darkfield light excluding tube which is built into the BX-URA2.(4

Page 22 - BXFM-F+BXFM-ILHS

LAMP HOUSING & ACCESSORIES28Unit: mmUnit: mmWeight: 1.6kgWeight: 210gLG-PS2*Light sourceLG-SFLight guideU-DULHADouble lamp house adapter8762352511

Page 23

CONTENTS2EYEPIECES/FILAR MICROMETER EYEPIECE --------------------------------- 33Widefield eyepieces WHN10x, WHN10x-H, CROSSWHN10x, WH15x ------------

Page 24 - ILLUMINATION UNITS

OBSERVATION TUBES29Weight: 350gø6057.6• For attachable video camera adapters, refer to video camera adapters system diagram page (pages 5-6).U-TLUSing

Page 25 - BX-KMA/BX-KMA-ESD

30OBSERVATION TUBES117.22361.981139.40088.0002.83770.330149.08120° 0' 0"42° 0' 0"95.929101.929318.527328.338337.71872.200Super wid

Page 26 - Unit: mm

Intermediate tubesVarious accessories for various observation need.31INTERMEDIATE TUBES & ACCESSORIES4542ø75ø70ø13896 42Unit: mmWeight: 1.3kgU-ECA

Page 27 - Lamp housings

INTERMEDIATE TUBES & ACCESSORIES32Weight: 1kgU-DPDual portUse this intermediate tube to divide the light path.Weight: 500gU-DP1xCDual port 1xCombi

Page 28 - Lamp housing accessories

EYEPIECES/FILAR MICROMETER EYEPIECE33EyepiecesEyepieces for UIS2 optical system.Filar micrometer eyepieceU-OSMUsed for precise measurement in the fiel

Page 29 - Weight: 210g

REVOLVING NOSEPIECESU-P4RECenterable quadruple revolving nosepiece with slider slot for DICU-P6RECenterable sextuple revolving nosepiece with slider s

Page 30 - Single port tube with lens

REVOLVING NOSEPIECESJAPAN2A00002JAPANU-D6BDREU-D6BDREø102.44048.234.8 76.4104(111.2)4048.2ø102.438 76.4(114.4)104116.540Ø116.5(125.6)38 87.647.2U-D6BD

Page 31 - OBSERVATION TUBES

362/3" CCD1/2" CCDField of view (F.N.)Projection areaPractical field of view (mm) =Projection area (Field Number)Objective lens magnificatio

Page 32 - Intermediate tubes

Video camera portThis port can be attached directly to the trinocular observation tube as well as to the single port tube with lens. VIDEO CAMERA ADA

Page 33 - Weight: approximately 500g

MOTORIZED UNITS38(169)8440454187(487)40064.881.5211.586.21158010811.812107Illuminator cable length: 1.800mm Weight: 5.5kg(exclude objective lens)I

Page 34 - Filar micrometer eyepiece

light between the objective lens and tube lens,allowing the creation of user-specific or task-specific optical systems. To establish real flexibility

Page 35 - REVOLVING NOSEPIECES

MOTORIZED UNITS3968.3190.5115U-D5BDREMCMotorized quintuple BD revolving nosepiece with slider slot for DICU-D6REMCMotorized sextuple revolving nosepie

Page 36

MOTORIZED UNITS40Unit: mmø78R88147.5108135170.5148312.595658.258.414.862.571* Consult your Olympus dealer about the motorized focus.Cable length: 2000

Page 37 - C-mount video camera ports

MOTORIZED UNITS415177206310.577133341.63345656169925470 475.582.35091.52107010021410433.63BXFMA-FMotorized illumination with power focusA motorized mi

Page 38 - Video camera mount adapters

DEEP ULTRAVIOLET OBSERVATION SYSTEM42Deep ultraviolet observation systemThis module adds a deep ultraviolet (248nm) optical system to a general micros

Page 39 - Motorized units

1. Field Number (F.N.) and Practical Field of ViewThe field number (F.N.) is referred to as the diaphragm size ofeyepiece in mm unit which defines the

Page 40 - Weight: 1.1kg

•Total magnification on the video monitor:m(ob)=50×, M(video camera adapter) is 0.5× from Figure 1 and monitormagnification is 46.2× from Figure 3.M(m

Page 41 - MOTORIZED UNITS

9. AberrationsA difference between an ideal image and an actual image thatpasses through an optical system is called an “aberration.”9.1 Requirements

Page 42

(4) Field curvatureAn image plane of an object on a plane perpendicular to anoptical axis does not always become a plane perpendicular tothe optical a

Page 43 - U-UVF5FB 80g

Specifications are subject to change without any obligation on the part of the manufacturer.Printed in Japan M1606E-1106B•OLYMPUS CORPORATION has obta

Page 44 - OPTICAL TERMINOLOGY

4. LighteningWeight has been reduced to approximately 2/3that of conventional products by using analuminum objective lens barrel cover. This hasthe ef

Page 45

5SYSTEM DIAGRAM56SHUTTERSHUTTER56SHUTTERU-ANU-AN360-3U-AN360IRLG-SFLG-PS2U-LH100HGAPOU-LH100HGU-LH75XEAPOU-LH100-3U-LH100L-3U-LH100IRSuper widefield t

Page 46

6SYSTEM DIAGRAMMOTORIZED UNIT SYSTEM DIAGRAMBXFM-A SYSTEM DIAGRAMSee manualU-D5BDREMCU-D6REMCU-FWOBX-RFAAU-AN360RAFU-AFA1MBX-RLAAU-LH100-3U-LH100L-3U-

Page 47

7UIS2/UIS OBJECTIVE LENSESMPL(Plan)FLN-100 BD Objective lens series list Meaning of abbreviations shown on objective lens Objective lens notation

Page 48 - Printed in Japan M1606E-1106B

UIS2 OBJECTIVE LENSES8M Plan SemiApochromatMPLFLN seriesPlan SemiApochromat objective lenses, giving high-level correction for chromatic aberration.

Comments to this Manuals