E-32
Maintenance of the threaded sections on the
TTL cable and TTL cable connector
If the threaded sections used to connect the TTL cable to the TTL cable connector are not
maintained properly, salt and other seawater residue may adhere the TTL cable and
prevent it from being disconnected.
After use in seawater, clean off any salt, sand, or other residue as soon as possible, then
dry the equipment thoroughly. Clean the threaded sections with a cotton swab and apply a
thin, uniform layer of O-ring silicon grease (provided with this case).
Maintenance of the TTL Connector Cap
After removing the TTL connector cap from the waterproof cap, be sure to clean and
grease the O-ring.
Use the waterproof cap maintenance adapter to remove the O-ring unit from the
waterproof cap.
Waterproof cap Waterproof cap
maintenance adapter
Insert the adapter by aligning its pin with the hole on the
cap.
Turn the adapter counterclockwise to remove the O-ring
unit.
After removing the O-ring attached to the O-ring unit, clean
the O-ring groove and apply silicon grease to the O-ring.
Then, re-attach the O-ring to the O-ring unit.
1
2
3
❈ Reverse the removal procedure to re-attach the O-ring unit to the waterproof cap.
O-ring
Clean and apply O-ring silicon
grease to these sections.
Comments to this Manuals